TULA.VN - Electronics Materials and Instruments in Vietnam  
       TIẾNG VIỆT     
Home | Line Card | Letter | Site Map | Contact Us
            
DEVICE PROGRAMMER | INSTRUMENTS | MATERIALS | COMPONENTS | SERVICE ABOUT US | FAQ
 PDODUCTS
Device Programmers
»
Universal Programmer
»
Gang Programmer ¦
»
In-System Programmer
»
Specialized Programmer
»
Auto. Handler System
»
Sockets and Accessories
»
Eprom Eraser, IC Tester
»
HDD/memory Duplicator
»
Jig test ICT/FCT/DIP-pallet
Test and Measurement
»
Osciloscope, HDS, MSO
»
Spectrum/Network/Logic
»
Data Logger and Sensors
»
Digital Multimeter
»
Generator, Freq. couter
»
LCR, component tester
»
Power Supply, elec. load
Design, Assembly Tools
»
Training & Education KIT
»
Embedded Dept. Tools
»
Rework & Solder tools
»
SMT/ PCBA Equipments
Other electronics Tools
»
Automotive Tools
»
Telecom, Television
»
Optical, Force, Torque
Electronics components
»
MCU 8051-core series
»
Nuvoton ARM Cortex-M
»
Voice and Audio ICs
»
Nuvoton ARM7/9 Soc
»
Wireless RF IC, Tools
 Số lượt truy cập
We received

239075698
page views since 20/12/2006
 Ai đang online
There are currently, 0 guest(s) and 0 member(s) that are online.

You are Anonymous user. You can register for free by clicking here



OUR PARTNERS
(Products Line-Card)



Flash Support Group

PEmicro

Power Supply

Shenzhen KESD Technology Co.,Ltd.



Car and Consumer IC Solutions Provider


  

Category: Main/4. Electronics Tools, KITs and other field Instruments/4.3. Microscope, vision instruments and Force-Torque


      
  Model 205: Dual Beam Ozone Monitor™
  Part#: 2B Technologies Model 205
  Ghi chú: Máy đo nồng độ Ozone Model 205 Dual Beam
  Nhãn hiệu: 2B Technologies (Mỹ/USA)
  [ Tài liệu Datasheet ]   [ Quotation Quotation sheet ]   [ Shopping Shopping now ]   [ Views: 3559 ]   2021-04-07
 ◊ Đặc điểm chính:
The Model 205 Dual Beam Ozone Monitor makes use of two detection cells to improve precision, baseline stability, and response time.  In the Dual Beam instrument, UV light intensity measurements Io (ozone-scrubbed air) and I (unscrubbed air) are made simultaneously. Combined with other improvements, this made it possible to reduce the time between ozone measurements to 2 seconds, making our instrument the fastest UV-based ozone monitor on the market, while still retaining the small size, weight, and power requirements of our popular Model 202 Ozone Monitor.  Fast measurements are especially desirable for aircraft and balloon measurements where high spatial resolution is needed.  For 10-s averaging, a precision of 1.0 ppb is achieved.  Alternatively, one can choose to average more points internally to obtain even better precision.  Flash card memory and a long-life, quiet internal air sampling pump are now standard on the instrument.  The Model 205 Dual Beam Ozone Monitor has been approved by the EPA as a Federal Equivalent Method (FEM) based on a modification of the Model 202: EQOA-0410-190.

Schematic Diagram

Picture

 ◊ Mô tả chi tiết:

Features

  • Quiet long-life internal air pump (now standard)
  • Low power consumption (~8 watt)
  • Internal data logger (EEPROM), logs 16,383 lines of data
  • Real-time clock
  • Both serial and user-scalable analog voltage outputs (4-20 mA current output optional)
  • Flash card memory (SD card) for virtually unlimited, portable data storage
  • Three 0-2.5 VDC analog inputs for logging other measurements, such as external temperature, pressure, and humidity
  • Convenient user interface to microprocessor, including calibration parameters (gain and zero)
  • Selectable measurement time of 2 s or data averaging times of 10 s, 1 min, 5 min and 1 hr (custom averaging times available)
  • DewLine™ for elimination of any water vapor interference, a unique feature of 2B Tech instruments
  • Dual beam feature allows for heightened precision and improved baseline stability for applications where high spatial resolution is required.

Options

  • GPS for continuous logging of latitude, longitude, and altitude (for 10-s data mode and above)
  • Rechargeable lithium-ion battery provides 12 hours of continuous operation
  • External particle filter
  • Serial-to-USB adapter
  • 4-20 mA analog current output
  • Bluetooth for wireless data transmission
  • Low-temperature package for operation to -20 degrees C (pump, lamp heater)
  • High-altitude upgrade (pressure sensor for use up to 25 km altitude)
  • Extra long-life, low temperature internal air pump
  • Low-power option for even lower power consumption
  • Rack-mount case configuration

Applications

The fast, accurate, and precise measurements of the Model 205 Dual-Beam Ozone Monitor--combined with its portability, small size, and versatile data capabilities--have led to its use in many unique and challenging field applications.  Literally from pole to pole and points in between, the Model 205 has been used aboard aircraft, balloons, ships, trains, tower platforms, remote field stations, and others.  The application note here describes the use of a Model 205 on a light rail platform in Utah, resulting in some illuminating (and perhaps counterintuitive) findings about ozone levels near busy highways.

Specifications

Measurement PrincipleUV Absorption at 254 nm; Dual Beam
Federal Equivalent Method (FEM)Yes, EQOA-0410-190
Linear Dynamic Range0 to 250 ppm
Resolution0.1 ppb
Precision (1σ rms noise)Greater of 1.0 ppb or 2% of reading for 10-s average
AccuracyGreater of 1.0 ppb or 2% of reading
Limit of Detection (2σ)2.0 ppb for 10-s average
NIST-Traceable CalibrationYes
Measurement Interval2 s (Data averaging options: 10 s, 1 min, 5 min, 1 hr)
Flow Rate (nominal)~1.8 Liter/min
Flow Rate Requirement>1.2 L/min
Baseline Drift< 1 ppb/day
< 3 ppb/year
Sensitivity Drift< 1%/day
< 3%/year
Measurement Time, Frequency2 s, 0.5 Hz
Response Time, 100% of Step Change4 s, 2 points
Measurement and Averaging Times2 s, 10 s, 1 min, 5 min, 1 hr
Ozone Unitsppb, pphm, ppm, µg m-3, mg m-3
Pressure Unitsmbar, torr
Temperature Units°C, K
T and P CorrectedYes
Operating Temperature Range0 to 50 °C standard; optional -20 to 50 °C with low temperature modifications (pump and lamp heater cold-weather package)
Operating Altitude Range~0-13.5 km (150-1,013 mbar) standard; optional ~0-25 km (30-1,013 mbar) with upgraded pressure sensor
Power Requirement;
Supplied by battery or 110/220 VAC Power Pack
12 V dc or 120/240 V ac, nominally 650 mA at 12 V, ~8 watt (~7 watt with cell heater unplugged)
Size3.7 x 8.5 x 11.5 inches (9.5 x 21.5 x 30 cm)
Weight5.8 lb (2.6 kg); 3.1 lb (1.4 kg) without instrument case
Internal Data Logger Capacity16,383 lines (2-s fast measurement mode = 9.1 hr; 10 s avg. = 1.9 days;
1 min avg = 11 days; 5 min avg = 1.9 mo; 1 hr avg = 1.9 yr
SD Card Logger Capacity> 2 GB (> 5-year capacity for 10-s averaging mode)
Analog Inputs for Internal Logging of Other Instruments3 Analog Inputs, 0-2.5 V; For example, could log external T, P, and RH
Data OutputsRS232, 0-2.5 V Analog, LCD Display, External USB Converter (Optional 4-20 mA Current; request quote)
Data Transfer Baud Rates2400, 4800, 19200
Output RangesUser-Defined Scaling Factor in Menu
DewLine™Yes
Quiet, Long-Life Internal Air PumpYes
Flow MeterYes
OptionsBattery; External Particle Filter; Serial-to-USB Adapter; GPS (for 10-s data mode and above); Bluetooth; 4-20 mA Current Output; Cold-Weather Package (pump, lamp heater); High-Altitude Upgrade (pressure sensor); Extra-Long-Life, Low-Temperature Internal Air Pump; Low-Power Option; Rack-Mount Case Configuration

System Includes

  • Model 205 Dual Beam Ozone Monitor
  • Quiet, Long-Life Internal Air Pump
  • AC Power Adapter (100-240 VAC to 12 VDC) with Country-Specific Plug
  • Cigarette Lighter Adapter 
  • Battery Wire Connector
  • Zeroing Cartridge
  • Flash Card Memory for virtually unlimited, portable data storage
  • SD Card (> 2 GB) and SD Card Reader
  • Operation Manual on USB Stick
  • Calibration Data and NIST-Traceable Calibration Certificate
  • Instrument Birth Certificate
  • One-Year Warranty





CÁC SẢN PHẨM KHÁC CÙNG NHÀ SẢN XUẤT / OTHER PRODUCTS FROM 2B Technologies
Model 205: Dual Beam Ozone Monitor™



Thao tác người sử dụng: [ Add Download ]

 





CONDITTION AND USING TERMS

TULA Solution Co., Ltd - Công ty TNHH Giải pháp TULA
Headquater: No. 173 Group 15, Dong Anh District, Hanoi 10000, Vietnam
Head-Office: No. 6 Lane 23, Đình Thôn street, Mỹ Đình ward, Nam Từ Liêm Dist., Hà Nội, Vietnam
Tel.: +84-24.39655633,  Hotline: +84-912612693,  E-mail: info (at) tula.vn

 
Copyright © 2005-2023, TULA Solution Co., Ltd. All right reservedABOUT US | FAQ