| Device Programmers |
| Universal Programmer |
| Gang Programmer ¦ |
| In-System Programmer |
| Specialized Programmer |
| Auto. Handler System |
| Sockets and Accessories |
| Eprom Eraser, IC Tester |
| HDD/memory Duplicator |
| Jig test ICT/FCT/DIP-pallet |
| Test and Measurement |
| Osciloscope, HDS, MSO |
| Spectrum/Network/Logic |
| Data Logger and Sensors |
| Digital Multimeter |
| Generator, Freq. couter |
| LCR, component tester |
| Power Supply, elec. load |
| Design, Assembly Tools |
| Training & Education KIT |
| Embedded Dept. Tools |
| Rework & Solder tools |
| SMT/ PCBA Equipments |
| Other electronics Tools |
| Automotive Tools |
| Telecom, Television |
| Optical, Force, Torque |
| Electronics components |
| MCU 8051-core series |
| Nuvoton ARM Cortex-M |
| Voice and Audio ICs |
| Nuvoton ARM7/9 Soc |
| Wireless RF IC, Tools |
|
|
|
We received
249490685 page views since 20/12/2006 |
There are currently, 0 guest(s) and 0 member(s) that are online.
You are Anonymous user. You can register for free by clicking here |
OUR PARTNERS
(Products Line-Card)
|
| | Category: Main/2. Test and Measuament Equipments/2.0. Digital Storage & Analog Oscilloscope
| | | | ◊ Đặc điểm chính: | | Adopts the Rogowski coil current measurement system: within the range, the output signal of the system and the current signal to be measured are always linear, so the accuracy will not change with the current; The RCP500 measures AC current up to 500A pk, minimum to 200mA pk, with bandwidth ranging from 15Hz to 300KHz, 1% accuracy, and has less than 2mV noise. Directly powered by Micsig UPI interface, realise auto scaling setup. Bandwidth:15-300KHz(-3dB)
Current range:200mApk-500Apk Output Sensitivity:10mV/A Typical Accuracy:1% |
|
|
Key Specifications |
Model | RCP500 | Bandwidth | 15-300KHz (-3dB ) | Current range | 200mApk-500Apk | Output Connector | Powered BNC / External BNC | Output Sensitivity | 10mV/A | Typical Accuracy | 1% | Phase Accuracy | ≤0.8° (45Hz-66Hz) | Temperature Coefficient | Operating temp. range + 0.05 × Accuracy Specification /℃ (23℃±5℃) | Conductor Positional Accuracy | Within ±1% (Deviation from the Center) | Influence of External Magnetic Fields | 1.5% f.s. or below (400A/m,50Hz/60Hz) | Offset Voltage | ±1mV or below | Max Voltage | AC 10kV RMS (1 minute), (50Hz/60Hz) (Rogowski coil part only) | Output Impedance | High resistance | Output Noise | <2mv rms | Conductor Under Test Diameter | ≤Φ50mm | Power Supply | DC 5V | Coil to Integrator Cable Length | 2m (customizable) | Integrator Dimensions | 37*22*82mm | Rogowski Coil Inner Diameter | 50mm(customizable) | Rogowski Coil Thickness | Approx. φ6mm | Environmental Characteristics | Operating Temperature | -20-70℃ | Storage Temperature | -30℃-70℃ | Operating Humidity | Max 80%,no condensation | Operating Altitude | ≤ 2000m | Operating Place | Indoor use, Pollution Degree 2. |
CÁC SẢN PHẨM KHÁC CÙNG NHÀ SẢN XUẤT / OTHER PRODUCTS FROM MICSIG |
|
|
| | |
OUR GLOBAL PARTNERS
Minato, Leap, SMH-Tech, Xeltek, Elnec, Conitec, DediProg, Phyton, Hilosystems, Flash Support Group, PEmicro ||Rigol, Tonghui, Copper Mountain, Transcom, APM || Atten, Zhuomao, Puhui, Neoden, Ren Thang, Genitec, Edry, UDK ||
CONDITTION AND USING TERMS
TULA Solution Co., Ltd - Công ty TNHH Giải pháp TULA
Headquater: No. 173 Group 15, Dong Anh District, Hanoi 10000, Vietnam
Head-Office: No. 6 Lane 23, Đình Thôn street, Mỹ Đình ward, Nam Từ Liêm Dist., Hà Nội, Vietnam
Tel.: +84-24.39655633, Hotline: +84-912612693, E-mail: info (at) tula.vn |