| Device Programmers |
| Universal Programmer |
| Gang Programmer ¦ |
| In-System Programmer |
| Specialized Programmer |
| Auto. Handler System |
| Sockets and Accessories |
| Eprom Eraser, IC Tester |
| HDD/memory Duplicator |
| Jig test ICT/FCT/DIP-pallet |
| Test and Measurement |
| Osciloscope, HDS, MSO |
| Spectrum/Network/Logic |
| Data Logger and Sensors |
| Digital Multimeter |
| Generator, Freq. couter |
| LCR, component tester |
| Power Supply, elec. load |
| Design, Assembly Tools |
| Training & Education KIT |
| Embedded Dept. Tools |
| Rework & Solder tools |
| SMT/ PCBA Equipments |
| Other electronics Tools |
| Automotive Tools |
| Telecom, Television |
| Optical, Force, Torque |
| Electronics components |
| MCU 8051-core series |
| Nuvoton ARM Cortex-M |
| Voice and Audio ICs |
| Nuvoton ARM7/9 Soc |
| Wireless RF IC, Tools |
|
|
|
We received
238958407 page views since 20/12/2006 |
There are currently, 0 guest(s) and 0 member(s) that are online.
You are Anonymous user. You can register for free by clicking here |
OUR PARTNERS
(Products Line-Card)
|
| | Category: Main/3. Electronics Equipments & Systems for embedded electronics design and PCB assembly/3.3. Solder Tools and rework systems
| | | | ◊ Đặc điểm chính: | | Model TM-100P-IO-2H is specifically designed to perform soldering of FPC, PCB or LCD. This system is versatile equipment, which can be used to perform many types of processes. Other models are available for selection for specific operation. Many considerations are put into the system to ensure reliable performance.
Warning
Isolate power supply before removing side cover and electrical connections.
Cô lập nguồn điện trước khi tháo nắp bên và các kết nối điện.
|
|
|
Chapter 1: Machine Overview
This chapter describes the basic information of this product such as method of heating,
machine components and features etc.
1.1 Method of Heating
This system employs current as a heating source versus the conventional method of
heating using a heater rod. This method of heating is also commonly known as resistance
heating, which enables spontaneous control of heat energy due to the small size of the
thermode which allows almost instant heating and cooling. The entire heating process is
achieved by varying the current supply to the thermode.
1.2 Machine Components
The system can be divided into the following modules:
1) Thermode assembly
2) Silicone rubber or Polyamide tape spool assembly
3) Work table assembly
4) Vision system
5) Mobile structure for transportability
1.3 Machine Features
- 7” touch screen panel for parameter input
- XYZ adjustment mechanism for CCD camera
- IR LED light source
- Air blower to accelerate cooling
- Build in vacuum ejectors to control fixture vacuum
- Levelling mechanism on work table
- Caster wheel for mobility
- Ergonomically positioned input switches
1.4 Machine specifications
Input voltage |
220VAC±10%, 50 or 60Hz |
Power |
8.0kVA |
Air supply |
Filtered clean air, 5-7 bars |
Operating ambient |
18-28ºC, 40-80% humidity with no significant dust |
Heating method |
Pulse Heat |
Bonding Force |
0.8kgf ~ 25kgf |
Temperature ramp profile |
4 stages |
Start Temp. |
30-300°C |
Ramp Temp. |
30-550°C |
Release Temp. |
30-550°C |
Hold period |
1-100s |
Ramp period |
1-25s |
Thermocouple type |
K-type |
Top Vision System Camera |
2 units of CCD |
Top Vision System Magnification |
38x |
Vacuum ejector |
2 units, -650mmhg each |
Max. Thermode size |
75 x 3mm |
Password |
User pre-set |
Built-in counter |
Yes |
Counter alarm |
Yes |
Program capacity |
100 |
Levelling mechanism |
Yes (confirm by using prescale paper) |
Table size |
120 x 120mm |
User interface |
Touch screen LCD |
Real time temperature profile |
Yes |
Substrate loading/unloading |
Manual |
Over temperature protection |
Yes |
Machine Colour |
Off grey and grey |
Machine dimensions |
1250mm (L) X 830mm (D) X 1475mm (H) |
Machine Weight |
< 320kg |
Chapter 2: Safety and Precautions
1) Read this operation manual to make sure of correct operation before starting
installation, wiring, operation and maintenance, and inspection of the machine.
2) Turn off the power to the machine before starting installation, removal, wiring,
maintenance, and inspection of the machine. Failure to turn power off may cause
electrical shocks or fire hazard.
3) Only trained service personnel are to install, wire, program, and operate the
machine. Personnel without such expertise should not use the machine.
4) Take precaution while moving or transporting the machine to prevent the machine
from falling, otherwise damage or malfunction of the machine will result.
5) Make sure of safety when operating the machine. Incorrect operation on the
machine may cause machine damage or accidents.
6) Install the machine in environments described in this operation manual. If the
machine is used in places where the machine is subjected to high-temperature,
high-humidity, condensation, corrosive gases, excessive vibrations, and excessive
shocks, then electrical shocks, fire hazard, or malfunction will result.
7) Ensure all machines’ safety covers are properly installed prior to operation.
8) During operation, do not place object along or on mechanism movement path.
9) During operation, keep clear of all fixtures or work stage and any mechanism
movement path.
10)Do not attempt to open the cover without first disconnecting power supply. Service
should only be carried out by qualified personnel. Have a thorough understanding
on the system before operating the system.
11)Wear safety goggle and use proper tools and equipment when conducting
machine maintenance or troubleshooting
CÁC SẢN PHẨM KHÁC CÙNG NHÀ SẢN XUẤT / OTHER PRODUCTS FROM CHERUSAL |
|
|
| | |
OUR GLOBAL PARTNERS
Minato, Leap, SMH-Tech, Xeltek, Elnec, Conitec, DediProg, Phyton, Hilosystems, Flash Support Group, PEmicro ||Rigol, Tonghui, Copper Mountain, Transcom, APM || Atten, Zhuomao, Puhui, Neoden, Ren Thang, Genitec, Edry, UDK ||
CONDITTION AND USING TERMS
TULA Solution Co., Ltd - Công ty TNHH Giải pháp TULA
Headquater: No. 173 Group 15, Dong Anh District, Hanoi 10000, Vietnam
Head-Office: No. 6 Lane 23, Đình Thôn street, Mỹ Đình ward, Nam Từ Liêm Dist., Hà Nội, Vietnam
Tel.: +84-24.39655633, Hotline: +84-912612693, E-mail: info (at) tula.vn |